Showing posts with label THz Pulse. Show all posts
Showing posts with label THz Pulse. Show all posts

Monday, 6 July 2020

Optical constants of CuO and ZnO particles in the terahertz frequency range

 Calvo-de la Rosa, Jaume, Alexandre Locquet, Denis Bouscaud, Sophie Berveiller, and D. S. Citrin. "Optical constants of CuO and ZnO particles in the terahertz frequency range." Ceramics International (2020).

Abstract
The optical constants (complex dielectric function) of CuO and ZnO particles in polyethylene pellets are measured by terahertz time-domain spectroscopy. The determination of the dielectric properties of these materials is of interest for energy-storage applications, for instance. Maxwell-Garnett theory is used to extract the contribution to the frequency-dependent optical constants of the oxide powders. The validity of the assumptions of Maxwell-Garnett theory are experimentally verified and self-consistency of the results of the model confirmed. On this basis, experimental complex permittivity values for isotropic CuO and ZnO oxide powders are reported in the 100 GHz-3 THz range.

"THz transmission data through the pellets were obtained using a TeraView TPS Spectra 3000 in transmission mode. The experimental bandwidth (power spectrum of "

Monday, 1 June 2015

An Effective Method for Substance Detection Using the Broad Spectrum THz Signal with a “Terahertz Nose”

Vyacheslav A. Trofimov  and Svetlana A. Varentsova 



Abstract

We propose an effective method for the detection and identification of dangerous substances by using the broadband THz pulse. This pulse excites, for example, many vibrational or rotational energy levels of molecules simultaneously. By analyzing the time-dependent spectrum of the THz pulse transmitted through or reflected from a substance, we follow the average response spectrum dynamics. Comparing the absorption and emission spectrum dynamics of a substance under analysis with the corresponding data for a standard substance, one can detect and identify the substance under real conditions taking into account the influence of packing material, water vapor and substance surface. For quality assessment of the standard substance detection in the signal under analysis, we propose time-dependent integral correlation criteria. Restrictions of usually used detection and identification methods, based on a comparison between the absorption frequencies of a substance under analysis and a standard substance, are demonstrated using a physical experiment with paper napkins.